このエントリーをはてなブックマークに追加
ID 55281
フルテキストURL
著者
Yatake, Hidetoshi Department of Radiology, Breast Cancer Center, Kaizuka City Hospital
Sawai, Yuka Department of Radiology, Breast Cancer Center, Kaizuka City Hospital
Nishi, Toshio Department of Breast Surgery, Breast Cancer Center, Kaizuka City Hospital
Nakano, Yoshiaki Department of Breast Surgery, Breast Cancer Center, Kaizuka City Hospital
Nishimae, Ayaka Department of Breast Surgery, Breast Cancer Center, Kaizuka City Hospital
Katsuda, Toshizo Department of Health Science, Osaka Butsuryo University
Yabunaka, Koichi Department of Gerontological Nursing/Wound Care Management, Graduate School of Medicine, University of Tokyo
Takeda, Yoshihiro Graduate School of Health Science, Okayama University Kaken ID publons researchmap
Inaji, Hideo Department of Breast Surgery, Breast Cancer Center, Kaizuka City Hospital
抄録
BACKGROUND:  The objective of the study was to compare direct measurement with a conventional method for evaluation of clip placement in stereotactic vacuum-assisted breast biopsy (ST-VAB) and to evaluate the accuracy of clip placement using the direct method.  METHODS:  Accuracy of clip placement was assessed by measuring the distance from a residual calcification of a targeted calcification clustered to a clip on a mammogram after ST-VAB. Distances in the craniocaudal (CC) and mediolateral oblique (MLO) views were measured in 28 subjects with mammograms recorded twice or more after ST-VAB. The difference in the distance between the first and second measurements was defined as the reproducibility and was compared with that from a conventional method using a mask system with overlap of transparent film on the mammogram. The 3D clip-to-calcification distance was measured using the direct method in 71 subjects.  RESULTS:  The reproducibility of the direct method was higher than that of the conventional method in CC and MLO views (P = 0.002, P < 0.001). The median 3D clip-to-calcification distance was 2.8 mm, with an interquartile range of 2.0-4.8 mm and a range of 1.1-36.3 mm.  CONCLUSION:  The direct method used in this study was more accurate than the conventional method, and gave a median 3D distance of 2.8 mm between the calcification and clip.
キーワード
Breast cancer
Direct methods
Mammography
Mask methods
Stereotactic vacuum assisted biopsy
発行日
2017-07
出版物タイトル
Breast Cancer
24巻
4号
出版者
Japanese Breast Cancer Society
開始ページ
593
終了ページ
600
ISSN
1340-6868
NCID
AA1103354X
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.ja
論文のバージョン
author
PubMed ID
DOI
Web of Science KeyUT
関連URL
https://doi.org/10.1007/s12282-016-0743-y