抄録

The Thoratec (Vectra) polyurethane vascular access graft (TPVA) is among the most recent additions to the list of materials used to construct prosthetic grafts for vascular access during hemodialysis. We give the TPVA very high marks, and recognize the utility of such a graft for use in hemodialysis. However, the strong elasticity of this graft can lead to unexpected complications after suturing. We devised a new surgical method using a TPVA-ePTFE (expanded polytetrafluoroethylene) composite graft, substituting the anastomosis section of the TPVA with a portion of ePTFE graft material, and have been able to overcome most of the TPVA's potential problems. We herein describe the technique.