ID | 54825 |
フルテキストURL | |
著者 |
Okada, Yoshiki
Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Abe, Nobuhiro
Department of Orthopaedic Surgery and Sport Medicine, General Medical Center Kawasaki Medical School
Hisamori, Noriyuki
Department of Science and Engineering, Sophia University
Kaneeda, Toshiaki
Department of Mechanical System Engineering, Okayama University of Science
Moriyama, Shigeaki
Department of Mechanical Engineering, Fukuoka University
Ohmori, Hitoshi
Riken Ohmori Materials Fabrication Laboratory
Mizutani, Masayoshi
Department of Mechanical Systems and Design, Graduate School of Engineering, Tohoku University
Nakashima, Yoshio
Nakashima Medical Co., Ltd.
Yokoyama, Yusuke
Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Ozaki, Toshifumi
Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Kaken ID
publons
researchmap
|
抄録 | Metals have been used clinically as biomaterials, especially in the orthopaedic and dental fields. Metals used as implants wear at contact surfaces, producing metal particles and metal ions that may be harmful. Newly developed metal implants and methods of implant surface modification are currently under scrutiny. We evaluated the use of electrolytic in-process dressing (ELID) as a surface finishing method for metal implants. Metal implants processed using the ELID method (ELID group) or not processed (Non-ELID group) were inserted surgically into rabbit femurs. The rabbits were sacrificed postoperatively over a 24-week period. We assessed the concentrations of the cytokines, interleukin (IL)-1β, IL-6, and tumor necrosis factor-α, the resistance to implant pull-out, and histopathology at the implant site. There was no significant difference between the groups regarding the cytokine concentrations or implant pull-out resistance. Many particles indicating wear around the implant were noted in the Non-ELID group (n=10) but not the ELID group (n=13), while a fibrous membrane adhering to the every implant was noted in the ELID group. The formation of a fibrous membrane rather than metal particles in the ELID group may indicate improved biocompatibility, and it suggests that ELID may prevent corrosion in the areas of contact.
|
キーワード | biomaterial
surface modification
metal implant
wear
metal ion
|
発行日 | 2017-02
|
出版物タイトル |
Acta Medica Okayama
|
巻 | 71巻
|
号 | 1号
|
出版者 | Okayama University Medical School
|
開始ページ | 49
|
終了ページ | 57
|
ISSN | 0386-300X
|
NCID | AA00508441
|
資料タイプ |
学術雑誌論文
|
言語 |
英語
|
著作権者 | CopyrightⒸ 2017 by Okayama University Medical School
|
論文のバージョン | publisher
|
査読 |
有り
|
PubMed ID | |
Amo Type | Original Article
|
Submission Path | amo/vol71/iss1/7
|