土壌熱伝導率の測定と推定式の適用

諸泉 利嗣 岡山大学
佐藤 裕一 北里大学獣医畜産学部
佐藤 幸一 北里大学獣医畜産学部
佐々木 長市 弘前大学農学生命科学部
抄録
Thermal conductivity of soil samples were measured using a twin transient-state cylindrical-probe method. The system of measurement consists of DC power supply, data logger, personal computer, 100cc soil sample, reference material sample, and two heat probes. The typical results were as follows: (1) Thermal conductivity of soils increased according to an increase of soil water content. (2) The thermal conductivity of Toyoura sand was larger than one of Kuroboku soil. (3) The thermal conductivity estimated by de Vries model had good agreement with the measured value.
キーワード
Thermal conductivity
Twin transient-state cylindrical-probe method
de Vries model
Volumetric water content
ISSN
1341-9099
NCID