このエントリーをはてなブックマークに追加
ID 14148
JaLCDOI
Sort Key
5
FullText URL
Author
Ishimaru, Kazuhito
Konishi, Masami
Nishi, Tatsushi
Abstract
In reactor furnace, due to high temperature and high pressure, data can be measured only near the furnace wall. In this paper, the way to estimate temperature distribution in a reactor furnace using measured data near the furnace walls and to control temperature distribution to the desired temperature distribution was studied. In the estimation, SQP method is employed using measured data near the furnace walls. As the result, the whole temperature distribution in a furnace could be obtained from such limited data. Furthermore, to control the temperature distribution in a reactor furnace, gas flow from multiple tuyeres and supplying material for controlling temperature distribution in a reactor furnace were determined by the SQP method. It was shown that temperature distribution in a furnace was regulated to achieve various desired distribution. Thus, it was verified that complicated temperature distribution in a reactor furnace could be controlled by combining furnace simulation and SQP method.
Publication Title
Memoirs of the Faculty of Engineering, Okayama University
Published Date
2005-01
Volume
volume39
Issue
issue1
Publisher
Faculty of Engineering, Okayama University
Publisher Alternative
岡山大学工学部
Start Page
28
End Page
39
ISSN
0475-0071
NCID
AA10699856
Content Type
Departmental Bulletin Paper
OAI-PMH Set
岡山大学
language
English
File Version
publisher
NAID
Eprints Journal Name
mfe