このエントリーをはてなブックマークに追加
ID 55631
FullText URL
Fig.pdf 173 KB
Author
Tachibana, Motomi Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Nishii, Nobuhiro Department of Cardiovascular Therapeutics, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Morimoto, Yoshimasa Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Kawada, Satoshi Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Miyoshi, Akihito Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Sugiyama, Hiroyasu Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Nakagawa, Koji Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Watanabe, Atsuyuki Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Nakamura, Kazufumi Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Morita, Hiroshi Department of Cardiovascular Therapeutics, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Ito, Hiroshi Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Abstract
BACKGROUND: In order to minimize inappropriate shocks of subcutaneous implantable cardioverter-defibrillators (S-ICD), it is important to recognize who is suitable for S-ICD indication. This study aimed to clarify what types of cardiac disease are likely to fulfill the S-ICD screening criteria and ineligible factors for S-ICD in the standard 12-lead electrocardiogram (ECG). METHODS: A total of 348 patients with heart disease were enrolled. They were assessed by supine and standing ECG recording to simulate the 3 S-ICD sensing vectors and standard 12-lead ECG, simultaneously. Clinical and ECG characteristics were analyzed to compare the patients who are eligible and ineligible with S-ICD screening ECG indication. RESULTS: The mean age of study patients was 49±21 years and 244 (70%) were men. Nineteen percent of patients were unsuitable for S-ICD. There was no significant difference in ineligibility for S-ICD among cardiac diseases (p=0.48). Univariate analysis showed complete right bundle branch block (CRBBB), QRS-T discordance in lead II, and QRS-T discordance in 3 leads (I, II, and aVF) were more frequent in patients who were ineligible for S-ICD than in the eligible group. Multivariate regression analysis showed CRBBB and QRS-T discordance in 3 leads were independent predictors for ineligibility of S-ICD. CONCLUSION: There are no differences in eligibility of S-ICD among types of cardiac diseases. CRBBB and QRS-T discordance were independent predictors for ineligibility.
Keywords
Implantable cardioverter-defibrillator
Sudden cardiac death
Ventricular arrhythmia
Note
This is an Accepted Manuscript of an article published by Elsevier
Published Date
2017-07
Publication Title
Journal of Cardiology
Volume
volume70
Issue
issue1
Publisher
Japanese College of Cardiology
Start Page
23
End Page
28
ISSN
0914-5087
NCID
AN10070473
Content Type
Journal Article
language
English
OAI-PMH Set
岡山大学
Copyright Holders
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.ja
File Version
author
PubMed ID
DOI
Web of Science KeyUT
Related Url
isVersionOf https://doi.org/10.1016/j.jjcc.2016.11.014