Abstract
Conventional self-assembling peptide hydrogels are effective as topical hemostatic agents. However, there is a possibility to harm living tissues due to their low pH. The aim of the present study was to demonstrate the efficacy of SPG-178, a neutral self-assembling peptide hydrogel, as a topical hemostatic agent. First, we measured the bleeding duration of incisions made on rat livers after application of SPG-178 (1.0% w/v), SPG-178 (1.5% w/v), RADA16 (1.0% w/v), and saline (n = 12/group). Second, we observed the bleeding surfaces by transmission electron microscopy immediately after hemostasis. Third, we measured the elastic and viscous responses (G′ and G″, respectively) of the hydrogels using a rheometer. Our results showed that bleeding duration was significantly shorter in the SPG-178 group than in the RADA16 group and that there were no significant differences in transmission electron microscopy findings between the groups. The greater the G′ value of a hydrogel, the shorter was the bleeding duration. We concluded that SPG-178 is more effective and has several advantages: it is non-biological, transparent, nonadherent, and neutral and can be sterilized by autoclaving.
Published Date
2014-07-21
Publication Title
PLoS ONE
Volume
volume9
Issue
issue7
Publisher
Public Library Science
ISSN
1932-6203
Content Type
Journal Article
language
English
Copyright Holders
© 2014 Komatsu et al.