FullText URL NMC40_7_703.pdf
Author Nakashima, Masahiro| Shinya, Takayoshi| Oto, Takahiro| Okawa, Tomoyo| Takeda, Yoshihiro|
Keywords bronchiolitis obliterans syndrome forced expiratory volume function volume lung transplantation morphological volume
Note This is a accepted manuscript of Nakashima, Masahiro et. al. Diagnostic value of ventilation/perfusion single-photon emission computed tomography/computed tomography for bronchiolitis obliterans syndrome in patients after lung transplantation. Nuclear Medicine Communications. (2019) 40(7), 703-710. To see pulished version, see doi: 10.1097/MNM.0000000000001021.|
Published Date 2019-07
Publication Title Nuclear Medicine Communications
Volume volume40
Issue issue7
Publisher Lippincott, Williams & Wilkins
Start Page 703
End Page 710
ISSN 0143-3636
NCID AA10624879
Content Type Journal Article
language 英語
OAI-PMH Set 岡山大学
File Version author
PubMed ID 31022070
DOI 10.1097/MNM.0000000000001021
Web of Science KeyUT 000472672100006
Related Url isVersionOf https://doi.org/10.1097/MNM.0000000000001021
FullText URL BreastCancer_24_4_593.pdf BreastCancer_24_4_593_tbl_fig.pdf
Author Yatake, Hidetoshi| Sawai, Yuka| Nishi, Toshio| Nakano, Yoshiaki| Nishimae, Ayaka| Katsuda, Toshizo| Yabunaka, Koichi| Takeda, Yoshihiro| Inaji, Hideo|
Keywords Breast cancer Direct methods Mammography Mask methods Stereotactic vacuum assisted biopsy
Published Date 2017-07
Publication Title Breast Cancer
Volume volume24
Issue issue4
Publisher Japanese Breast Cancer Society
Start Page 593
End Page 600
ISSN 1340-6868
NCID AA1103354X
Content Type Journal Article
language 英語
OAI-PMH Set 岡山大学
Copyright Holders https://creativecommons.org/licenses/by-nc-nd/4.0/deed.ja
File Version author
PubMed ID 27878446
DOI 10.1007/s12282-016-0743-y
Web of Science KeyUT 000404221100015
Related Url https://doi.org/10.1007/s12282-016-0743-y
Author Aono, Kaname| Morimoto, Setsuo| Hashimoto, Keiji| Sato, Katashi| Joja, Ikuo| Kimoto, Shin| Ezoe, Hiroshi| Takeda, Yoshihiro| Miyake, Masayoshi| Hayashi, Hidehiro| Wakabayashi, Hisao| Tamai, Toyosato| Morino, Yasuo| Shiraishi, Noriyuki|
Published Date 1980-10-30
Publication Title 岡山医学会雑誌
Volume volume92
Issue issue9-10
Content Type Journal Article
Author Morino, Yasuo| Takeda, Yoshihiro| Morimoto, Setsuo| Miyake, Masayoshi| Hayashi, Hidehiro| Ezoe, Hiroshi| Kimoto, Shin| Joja, Ikuo| Hashimoto, Keiji| Aono, Kaname| Hayashi, Kyoichi| Takaoka, Kazuko| Oshima, Yukiko|
Published Date 1981-08-30
Publication Title 岡山医学会雑誌
Volume volume93
Issue issue7-8
Content Type Journal Article
Author Aono, Kaname| Morino, Yasuo| Tamai, Toyosato| Wakabayashi, Hisao| Morimoto, Setsuo| Hashimoto, Keiji| Sato, Katashi| Joja, Ikuo| Kimoto, Shin| Ezoe, Hiroshi| Takeda, Yoshihiro| Miyake, Masayoshi| Hayashi, Hidehiro|
Published Date 1981-02-28
Publication Title 岡山医学会雑誌
Volume volume93
Issue issue1-2
Content Type Journal Article
Author Nakamura, Tetsuya| Hiraki, Yoshio| Takeda, Yoshihiro| Yamamoto, Hiromichi| Niiya, Harutaka| Togami, Izumi| Shirakami, Toshiaki| Aono, Kaname| Akamatsu, Nobuo| Sekiba, Kaoru|
Published Date 1986-10-31
Publication Title 岡山医学会雑誌
Volume volume98
Issue issue9-10
Content Type Journal Article
Author Takeda, Yoshihiro|
Published Date 1984-04-30
Publication Title 岡山医学会雑誌
Volume volume96
Issue issue3-4
Content Type Journal Article
Author Togami, Izumi| Hiraki, Yoshio| Kimoto, Shin| Shirakami, Toshiaki| Ueda, Hiroyuki| Satoh, Nobuo| Nakamura, Tetsuya| Yamamoto, Hiromichi| Joja, Ikuo| Hashimoto, Keiji| Morimoto, Setsuo| Aono, Kaname| Takeda, Yoshihiro|
Published Date 1985-10-30
Publication Title 岡山医学会雑誌
Volume volume97
Issue issue9-10
Content Type Journal Article
Author Hashimoto, Keiji| Kimoto, Shin| Shirakami, Toshiaki| Joja, Ikuo| Hayashi, Hidehiro| Takeda, Yoshihiro| Togami, Izumi| Niiya, Harutaka| Ueda, Hiroyuki| Shimizu, Mitsuharu| Sugita, Katsuhiko| Hiraki, Yoshio| Aono, Kaname| Kaji, Mitsumasa|
Published Date 1986-04-30
Publication Title 岡山医学会雑誌
Volume volume98
Issue issue3-4
Content Type Journal Article
Author Joja, Ikuo| Sato, Nobuo| Fujishima, Mamoru| Kaji, Mitsumasa| Togami, Izumi| Niiya, Harutaka| Shirakami, Toshiaki| Yamamoto, Hiromichi| Takeda, Yoshihiro| Kimoto, Shin| Hashimoto, Keiji| Morimoto, Setsuo| Sugita, Katsuhiko| Hiraki, Yoshio| Aono, Kaname|
Published Date 1985-02-25
Publication Title 岡山医学会雑誌
Volume volume97
Issue issue1-2
Content Type Journal Article
Author Ueda, Hiroyuki| Hashimoto, Keiji| Jyoja, Ikuo| Kimoto, Shin| Takeda, Yoshihiro| Kaji, Mitsumasa| Sato, Nobuo| Nakamura, Tetsuya| Hino, Hiroyuki| Koyama, Naoki| Hiraki, Yoshio| Aono, Kaname|
Published Date 1985-02-25
Publication Title 岡山医学会雑誌
Volume volume97
Issue issue1-2
Content Type Journal Article
Author Takeda, Yoshihiro| Hiraki, Yoshio| Morimoto, Setsuo| Togami, Izumi| Shirakami, Toshiaki| Shiraishi, Noriyuki| Kimoto, Shin| Joja, Ikuo| Hashimoto, Keiji| Aono, Kaname|
Published Date 1985-02-25
Publication Title 岡山医学会雑誌
Volume volume97
Issue issue1-2
Content Type Journal Article
Author Noriyasu, Toshiaki| Hiraki, Yoshio| Takeda, Yoshihiro| Mimura, Hidehumi| Mitani, Masahiko| Nagayama, Masako| Kimoto, Shin| Kaji, Mitsumasa| Hashimoto, Keiji| Aono, Kaname|
Published Date 1988
Publication Title 岡山医学会雑誌
Volume volume100
Issue issue9-10
Content Type Journal Article
Author Hayashi, Hidehiro| Hiraki, Yoshio| Joja, Ikuo| Kashitani, Naoko| Miyake, Masayoshi| Yamamoto, Yoshio| Kanzaki, Noriko| Inoue, Nobuhiro| Noriyasu, Toshiaki| Hashimoto, Keiji| Takeda, Yoshihiro| Mizuta, Akihumi| Sugita, Katsuhiko| Aono, Kaname|
Published Date 1987-02-28
Publication Title 岡山医学会雑誌
Volume volume99
Issue issue1-2
Content Type Journal Article
Author Gao, Xianshu| Nakagawa, Tomio| Yamamoto, Michinori| Kuroda, Masahiro| Sakae, Katsuyoshi| Shimizu, Mitsuharu| Niiya, Harutaka| Takeda, Yoshihiro| Joja, Ikuo| Hiraki, Yoshio| Kawasaki, Shoji|
Published Date 1996-06-29
Publication Title 岡山医学会雑誌
Volume volume108
Issue issue3-6
Content Type Journal Article
Author 竹田 芳弘|
Published Date 1984-03-31
Publication Title
Content Type Thesis or Dissertation
JaLCDOI 10.18926/15290
Title Alternative Clinical evaluation was examined between mixed type barium sulfate suspensions "BarytgenHD" and "Barytgen"
FullText URL 007_2_105_112.pdf
Author Nobuhara, Eitarou| Takeda, Yoshihiro| Shibuya, Kohichi| Oguri, Nobuhiro| Arioka, Tadashi| Goto, Sachiko| Morioka, Yasuki| Niiya, Harutaka| Nakagiri, Yoshitada| Joja, Ikuo| Sugita, Katsuhiko| Hiraki, Yoshio|
Abstract 混合粒子型硫酸バリウムバリトゲンHD200w/v%懸濁液について,バリトゲン160w/v%懸濁液と比較検討を行った。懸濁液安定性は両者共良かった。臨床評価においては,付着性,胃小区描出能は同程度であり,辺縁の描出能は良かったが凝集・ムラ付き,気泡は多くみられ懸濁液濃度について検討を加える必要があると考える。飲み易さは,バリトゲンHD200w/v%懸濁液のほうが濃度が高いのにもかかわらず飲み易く好評であった。
Abstract Alternative Both barium sulfate suspensions, Barytgen HD and Barytgen, had good stability. Although significant difference was not abserved in coating and visualization of gastric area, BarytgenHD showed better marginal visualization of gastric margin. Further study is needed to improve the visualization of sticky coating of gastric mucosa and many bubbles. BarytgenHD was easily to drink instead of high density barium sulfate suspensions.
Keywords 造影剤 (contorast media) 硫酸バリウム (barium sulfate suspension) 消化管検査 (barium examination)
Publication Title 岡山大学医療技術短期大学部紀要
Published Date 1997-01-31
Volume volume7
Issue issue2
Start Page 105
End Page 112
ISSN 0917-4494
language 日本語
File Version publisher
NAID 120002307979
JaLCDOI 10.18926/15274
Title Alternative Clinical evaluation of barium sulfate suspensions "Barytgen HD" - Second report -
FullText URL 009_1_041_048.pdf
Author Nobuhara, Eitarou| Takeda, Yoshihiro| Niiya, Harutaka| Shibuya, Koichi| Morioka, Yasuki| Nakagiri, Yoshitada| Joja, Ikuo| Sugita, Katsuhiko| Hiraki, Yoshio|
Abstract 混合粒子型硫酸バリウム「バリトゲンHD」の懸濁液最適濃度について,検討を行った。懸濁液安定性は,200w/v%と190w/v%は良好であったが,180w/v%は不良で臨床使用には不向きであると思われた。臨床的評価において200w/v%と190w/v%は付着性,辺縁の描出能,胃小区描出能においては同程度であった。200w/v%に多く見られた凝集・ムラ付き,気泡は,190w/v%では少なくなった。飲み易さは,200w/v%,190w/v%とも飲み易いと評価されたが,190w/v%でより飲み易い傾向にあった。バリトゲンHDの最適懸濁液濃度は,190w/v%であると思われる。
Abstract Alternative Barium sulfate suspensions in 200w/v% and 190w/v% had good stability. But in 180w/v% it had worse stability. Significant difference was not observed in coating, visualization of gastric margin and gastric area between in 200w/v% and 190w/v%. Barium sulfate suspensions in 190w/v% had less sticky coating of gastric mucosa and fewer bubbles than 200w/v%. Barium sulfate suspensions in 190w/v% was easiest density to drink. 190w/v% seems to be most adequate density in our study.
Keywords 造影剤 (contrast medium) 硫酸バリウム (barium sulfate suspension) 消化管検査 (barium examination)
Publication Title 岡山大学医療技術短期大学部紀要
Published Date 1998-09-30
Volume volume9
Issue issue1
Start Page 41
End Page 48
ISSN 0917-4494
language 日本語
File Version publisher
NAID 120002307256
JaLCDOI 10.18926/15252
Title Alternative Extended-cycle processによる乳房撮影用増感紙/フィルムシステムの画質改善
FullText URL 009_2_083_090.pdf
Author Goto, Sachiko| Maruyama, Toshinori| Azuma, Yoshiharu| Nakagiri, Yoshitada| Takeda, Yoshihiro| Sugita, Katsuhiko| Kimura, Fumie| Kadohisa, Shigefumi|
Abstract Extended-cycle process is the term used for a processor in which the processing time has been prolonged usually to approximate 210 seconds. It has been known that the extended-cycle process of some single-emulsion films as used for mammography may enhance film contrast and increase film speed. So the speed was increased in lower speed and higher resolution system than conventional systems by means of using the extended-cycle process in this paper. We investigated how much the resolution of the system was kept. A single screen-single emulsion combination, Konica M-100/CM-H was employed as a low speed and high resolution system. This film after exposure was processed in the different combinations of developing temperatures, 30, 32 and 34℃, and processing time of 210 seconds. On the other hand, Konica M-200/CM-H was employed as a high speed system. This film was processed in the standard-cycle processing (34℃, 90 seconds). Those systems were compared on contrast, speed, screen-film blur and noise by a characteristic curve, MTF (modulation transfer function) and WS (wiener spectrum). Furthermore, the RMI 165 phantom was used to evaluate visibility of mammographic details of these systems. As a result, in the extended-cycle process at the developing temperatures of 32 or 34°C and processing time of 210 seconds for M-100/CM-H, it was possible to increase the speed as much as the higher speed system, M-200/CM-H. Then the contrast, the MTF and the visibility were also improved as compared to the higher speed system. Furthermore patient dose could be reduced at the developing temperature of 34℃ and processing time of 210 seconds in M-100/CM-H.
Abstract Alternative 通常,extended-cycle processは処理時間が約210秒に延ばされた現像機のために使われる用語である。乳房撮影に使われるような片面乳剤フィルムにおけるextended-cycle processは,フィルムコントラストを増し,感度をあげることが良く知られている。そこで,本論文ではextended-cycle processにより低感度,高解像度システムの感度を上げ,どの程度解像度が維持されるかを調べた。片面増感紙/片面フィルムの組合わせであるKonica M-100/CM-Hを低感度,高解像度システムとして用いた。露光後のフィルムは現像温度30,32, 34度,処理時間210秒の異なる組合わせで現像処理した。一方,高感度システムとしてKonica M-200/CM-Hを用い,このフィルムは標準現像(34℃,90秒)された。感度,増感紙/フイルムのぼけ,雑音に関して,特性曲線,MTF(modulation transfer function), WS(wiener spectrum)によってこれらのシステムを比較した。さらにこれらのシステムにおける乳房写真の細部視覚評価のためにRM165ファントムを使用した。その結果,M-100/CM-Hに対するextended-cycle process現像温度32, 34℃,処理時間210秒のextended-cycle processにおいて,高感度システムM-200/CM-Hと同等の感度を上げることが可能であった。そのとき,コントラスト,MTF,視覚的検出能も高感度システムより向上した。さらに,現像温度34℃,処理時間210秒では,被曝線量の低減が可能であった。
Keywords image quality mammography single screen-single emulsion film system high-resolution screen extended-cycle process
Publication Title 岡山大学医療技術短期大学部紀要
Published Date 1999-02-26
Volume volume9
Issue issue2
Start Page 83
End Page 90
ISSN 0917-4494
language 英語
File Version publisher
NAID 120002307881
JaLCDOI 10.18926/11735
Title Alternative Clinical application of the contrast media containing soft drinks for the X-ray examination of the stomach
FullText URL 006_015_021.pdf
Author Shibuya, Koichi| Nakagiri, Yoshitada| Azuma, Yoshiharu| Goto, Sachiko| Maruyama, Toshinori| Sugita, Katsuhiko| Okura, Yasuhiko| Natsukawa, Koichi| Tandani, Nobuyoshi| Nobuhara, Eitaro| Morioka, Yasuki| Takeda, Yoshihiro| Hiraki, Yoshio|
Abstract 胃X線検査の被験者を増やし、検査を円滑に行う上で造影剤である硫酸バリウム懸濁液の飲みにくさが障害の一つとなっている。これを改善する目的で、懸濁液に市販の粉末清涼飲料を混入したところ、64.2%の人が通常のものよりも飲みやすいと答えた。臨床上も造影剤の付着が悪くなったり、胃の蠕動を促進する等の問題は生じず、有用であると考えられた。
Abstract Alternative Barium sulfate suspensions are disliked by many people. This is one of the obstacles to increase persons who consult doctors and to have medical examinations smoothly. We mixed soft drinks into the suspensions to improve this problem. As a result, they were popular among 64.2% people, there were not any clinical troubles that the suspensions did not stick to the mucous membrane of the stomach well, the peristalsis of the sotmach were promoted, and so on. These results suggest that the contrast media containing soft drinks is useful for the X-ray examinations of the stomach.
Keywords 造影剤 (contrast media) 硫酸バリウム (barium sulfate suspension) 清涼飲料 (soft drinks) 消化管検査 (barium examination)
Publication Title 岡山大学医療技術短期大学部紀要
Published Date 1996-02-29
Volume volume6
Start Page 15
End Page 21
ISSN 0917-4494
language 日本語
File Version publisher
NAID 120002313345