このエントリーをはてなブックマークに追加
ID 33034
FullText URL
Author
Sabarudin, Akhmad
Oshima, Mitsuko
Motomizu, Shoji
Abstract
A sensitive analytical method for the determination of trace amounts of silicate in ultrapurified water was developed. The method is based on the formation of an ion associate of molybdosilicate with malachite green (MG) and the collection of the ion associate on a tiny membrane filter (diameter: 5 mm, and effective filtering diameter: 1 mm). The ion associate formed on the membrane filter is dissolved together with the membrane filter in 1 ml of methyl cellosolve (MC) and the absorbance of MC solution is measured at 627 nm by a flow injection-spectrophotometric detection technique. In this method, silicate in the original sample (ultrapurified water) is concentrated as the ion associate into a small volume of MC to get high sensitivity. As sample concentration takes place, the small amounts of silicate contained in the reagents used also become concentrated as the ion associate into MC. The original sample volumes are varied and evaporated to an identical volume. Therefore, the reagent added is fixed to the same volume. The absorbance increase linearly with increase in the original sample volume will be due only to silicate in the original samples (ultrapurified water). The resulting slopes obtained by varying the sample volumes are compared with the slope of the calibration graph, and thus named the slope comparison method (SCM). The SCM facilitates a more sensitive and accurate evaluation of silicate concentration in the samples than either common calibration method (CCM) or standard addition method (SAM) because it compensates for the influence of trace amounts of silicate contained in chemicals, reagent solution and solvent used. The calibration graph was constructed from 0 to 0.25 ng ml(-1) of Si and the detection limit was 10 pg ml(-1) (ppt) when 30 ml of samples was used. The standard deviation and relative standard deviation from six measurements of the reagent blanks were 0.0012 and 3.5%, respectively.
Keywords
slope comparison method
ultrapurified water
ion associate
molybdosilicate
malachite green
membrane filter
Note
Published with permission from the copyright holder.
This is published in Analytica Chimica Acta, 2005 Vol.532 Issue.1 pp.27-35
Publisher URL: http://dx.doi.org/10.1016/j.aca.2004.10.049
Direct access to Thomson Web of Science record
(C)2004 by Elsevier B.V.
Published Date
2005-05-07
Publication Title
Analytica Chimica Acta
Volume
volume532
Issue
issue1
Publisher
Elsevier Science B.V.
Start Page
27
End Page
35
ISSN
0003-2670
NCID
AA00524834
Content Type
Journal Article
language
English
Copyright Holders
Elsevier Science B.V.
File Version
author
Refereed
True
DOI
Web of Science KeyUT
Submission Path
analytical_chemistry/31