Environmental Research & Control
Published by Environmental Management Center, Okayama University

<Formerly known as>
岡山大学環境管理センター報 (4号-11号) 岡山大学環境管理施設報 (1号-3号)

<Availability>
Some items are not available because of decision by its author or publisher.

Improvement of heat environment of a gymnasium designed for dance lessons

鈴木 久雄 Kaken ID researchmap
Published Date
2010-12
Abstract
Nowadays,we experience severe hot climate during summer.Ambient temperature and wet bulb globe temperature (WBGT) in our gymnasium designed for dance lessons exceeded exposure limits of both school health and industrial health. Such environment was our direct concern for risk of heat related disorders among students, guests and staffs using the facility. The building was old, and heat insulation seemed to be insufficient compared to recent standards for the building of the same kind. Introduction of a new air conditioning system to the facility was supposed to be avoided according to energy conservation policy. We considered that applying high-albedo paint to the roof would reflex the solar infrared irradiation and block the heat influx, thus lowering the ambient temperature inside the gymnasium. The renovation of the roof resulted in improved ambient temperature and WBGT. We concluded that application of high-albedo paint might be a useful technique to control high ambient temperature in similar buildings and to reduce risk of heat related disorders.
Keywords
high-albedo paint
wet bulb globe temperature
heat stroke
Note
実践報告
ISSN
0917-1533
NCID
AN1024789X